Alignment Tab
The alignment tab is visible as soon as you enter the alignment mode. For more information, see Activating the Alignment Process.
You can perform Three-Point Alignment:
- Line-up an imported image with reference marks, such as the precision fiducials on a CorrMic Holder.
- Line-up features in an imported image with LM, EM and SEM images of the same features.
- Line-up a session of LM, EM and SEM imagery with previously acquired LM, EM and SEM imagery session.
With the three-point alignment process you can set the position, rotation, and scale of an image or tile. This is used to line the image or tile up with reference marks or other images. Once an image is lined up, it can be used as a reference (road map) to move the stage to control further image acquisition.
|
Parameter |
Description |
|
|---|---|---|
|
Alignment Mode |
Sets which data properties you can change during the alignment. |
|
|
- |
Translate Only |
Moves the item you are aligning in x and y only without changing its size or orientation. |
|
- |
Translate and Rotate Only |
Moves the item in x and y direction and changes its orientation. It does not change the scale of the item you are aligning. |
|
- |
Translate, Rotate and Scale Only |
Moves, reorients, and resizes the item you are aligning. It does not shear it. |
|
- |
Translate, Rotate, Scale and Shear |
Supports full three-point alignment. |
|
- |
Alignment Handles |
Displays alignment handles to rotate and resize the image. |
|
- |
3D Alignment |
Displays options to align an image in z direction and for three dimensional rotation. |
|
|
Mirrors the image horizontally. |
|
|
|
Mirrors the image vertically. |
|
|
|
Mirrors the image stack in z direction around the middle z-height. |
|
|
Relative Z Offset |
Only visible if 3D Alignment is selected. |
|
|
Step Size |
Only visible if 3D Alignment is selected. |
|
|
Set to current Global-Z |
Only visible, if 3D Alignment is selected and only active if the Global-Z slider is activated on the Dimensions tab. |
|
|
Apply 3D Rotation |
Only visible, if 3D Alignment is selected. |
|
|
- |
Rotation X-Axis |
Sets the rotation along the x-axis with the slider or input field. Click on the |
|
- |
Rotation Y-Axis |
Sets the rotation along the y-axis with the slider or input field. Click on the |
|
- |
Rotation Z-Axis |
Sets the rotation along the z-axis with the slider or input field. Click on the |
|
- |
Angle Step Size |
Sets the angle step size for the slider/input fields above. |
|
- |
View Cube Control |
With this cube control, you can rotate the stack interactively. It has a visual representation of the current stack (white box) and the cutting plane which is displayed in the 2D view above. |
|
- |
Presets |
Sets the View Cube Control to a predefined position. You can set it to the Default, or you can select an orientation from the dropdown of the button to show the Default, Viewer Perspective, Left, or Right orientation. |
|
- |
Manual Control |
Controls the orientation of the View Cube Control. |
|
Reset |
Resets the alignment as it was when you started this alignment operation. |
|
|
Clear |
Resets the alignment to where it was when the data was first acquired or imported. |
|
|
Finish |
Exits from the alignment operation, keeping the alignment you have established. |
|
|
Cancel |
Returns to the alignment as it was when you started, and exits from the alignment operation. |
|