Cutting Out a Volume from a Z-Stack
With the processing function Cut Out Regions you can define a region in your z-stack and cut it out as a volume.
- You have opened your z-stack in ZEN.
- On the Processing tab, select the Method Cut Out Regions.
- Under Parameters, click on Define Regions.
- The Define Regions Setup opens.
- In the Dimensions tab, use the Z-Position slider to go to the first z-slice where you want to mark your region of interest.
- In the Region Edit Section on the left, click on Draw and select the type of region you want to use (rectangular, circular, polygonal,...).
- In the image, draw your so-called support region to mark the structure of interest.
- Repeat the previous steps for the last slice where your structure of interest appears as well as for those slices in between where significant changes (in shape and/or position) of this structure take place.
- Click on Interpolate.
- Interpolated regions are created for all slices between the support regions. The interpolated regions are displayed with a slightly darker color.
- Use the Z-Position slider to move through your stack and examine whether the interpolated regions satisfyingly cover the structure of interest in your stack.
- If you find a slice where the interpolated region does not cover your structure of interest, draw a new support region on this slice and click on Interpolate again.
- When the entire structure is marked satisfyingly by the interpolated regions, click on Finish.
- The Define Region setup closes and your image with the newly created regions is displayed in the Analysis view.
- On the Processing tab, click on Apply.
- Your marked structure is now cut out of the z-stack and opened as a new image.