Exporting Multiscene Images
File Size Limitation
The export of images to most file formats is subject to limits of the file size that can be created (typically ca. 2 GB). For this reason, we recommend to use the Big TIFF-format. If this is not possible because the Big TIFF-format does not fit your needs, check if the image size does not exceed the resources of your computer when exporting your preferred format. A message will inform you, when the size exceeds your resources. You have the following options to work around:
- Resize the resolution to scale the image down with the Resize slider.
- Activate Original Data and deactivate Apply Display Curve and Channel Color.
- With a rectangle, select a region of interest to minimize the image itself.
- Activate Crop to Selection and Generate New Tiles to cut the image again into tiles using the row and column options.
To export multiscene images, see the following description. Not all the parameters are used in this example. For a description of all available export parameters, see Image Export.
- You have loaded a multiscene image.
- On the Processing tab, select the function Image Export. Alternatively, click File > Export/Import > Export or press Ctrl+6.
- The export options are displayed in the Parameters tool. Make sure that Show All is activated to see all options.
- In the File Type section, define the format for your image to be exported.
- Based on your selection, the displayed options might change.
- If you have selected Big TIFF, activate Merge All Scenes to combine all scenes of your ROI in one image. Deactivate the checkbox to export single files per scene.
- Activate Define Subset.
- The Scene, the Region and the Tiles sections are displayed.
- In the Scene section, from the drop-down menu, select which parts of the input image you want to use for the resulting image.
- In the Region section, from the drop-down menu, select if you want to export the full image or a rectangle region.
- If you select Rectangle Region, you can draw a rectangle in the image according to your needs.
- To change the folder where to save the images, for Export To click
.
- A file browser opens.
- Navigate to the folder and click OK.
- You have changed folder for saving.
- Define a Prefix for naming your exported images. The default prefix is the name of your image. For information on naming conventions, see Naming Convention for Image Export.
- Click Apply at the top of the Processing tab.