IncubationAirHeaterIsEnabled

Complete Command

ZenService.Hardware.IncubationAirHeaterIsEnabled

Input

 

Output

boolean

Description

Returns the state of the incubator.

IncubationAirHeaterTemperature

Complete Command

ZenService.Hardware.IncubationAirHeaterTemperature

Input

 

Output

double

Description

Returns the current temperature setpoint.

IncubationChannelXIsEnabled (X=1-4)

Complete Command

ZenService.Hardware.IncubationChannelXIsEnabled

Input

 

Output

boolean

Description

Returns the state for a specific incubation channel.

IncubationChannelXTemperature (X=1-4)

Complete Command

ZenService.Hardware.IncubationChannelXTemperature

Input

 

Output

double

Description

Returns the temperature for a specific channel.

IncubationCO2Concentration

Complete Command

ZenService.Hardware.IncubationCO2Concentration

Input

 

Output

Double

Description

Returns the current CO2 concentration setpoint.

IncubationCO2IsEnabled

Complete Command

ZenService.Hardware.IncubationCO2IsEnabled

Input

 

Output

Boolean

Description

Returns the state of the CO2 incubation system.

IncubationO2Concentration

Complete Command

ZenService.Hardware.IncubationO2Concentration

Input

 

Output

Double

Description

Returns the current O2 concentration setpoint.

IncubationO2IsEnabled

Complete Command

ZenService.Hardware.IncubationO2IsEnabled

Input

 

Output

Boolean

Description

Returns the state of the O2 incubation system.

IncubationCoolingChannelIsEnabled

Complete Command

ZenService.Hardware.IncubationCoolingChannelIsEnabled

Input

 

Output

Boolean

Description

Returns the state of the cooling system.

IncubationCoolingChannelTemperature

Complete Command

ZenService.Hardware.IncubationCoolingChannelTemperature

Input

 

Output

Double

Description

Returns the current cooling temperature.

IncubationHumidityIsEnabled

Complete Command

ZenService.Hardware.IncubationHumidityIsEnabled

Input

 

Output

Boolean

Description

Returns the state of the humidifier.

IncubationHumidityValue

Complete Command

ZenService.Hardware.IncubationHumidityValue

Input

 

Output

Double

Description

Returns the current humidity.

TriggerDigitalInX (X = ...)

The range of values for X depends on the IOcard configuration.

Complete Command

ZenService.Hardware.TriggerDigitalInX

Input

 

Output

Boolean

Description

Returns the state of a specific TriggerDigitalIn port.

TriggerDigitalOutX (X = ...)

The range of values for X depends on the IOcard configuration.

Complete Command

ZenService.Hardware.TriggerDigitalOutX

Input

 

Output

Boolean

Description

Returns the state of a specific TriggerDigitalOut port.

TriggerDigitalOutRLShutter

Complete Command

ZenService.Hardware.TriggerDigitalRLShutter

Input

 

Output

Boolean

Description

Returns the state of the reflected light shutter, where True = Open and False = Closed.

TriggerDigitalOutTLShutter

Complete Command

ZenService.Hardware.TriggerDigitalOutTLShutter

Input

 

Output

Boolean

Description

Returns the state of the transmitted light shutter, where True = Open and False = Closed.