RAM availability
Any data that the CPU processes must be held in the computer's Memory (usually shortened to RAM). But we also need enough RAM to hold the result of the operation, which means we need twice as much RAM as the data we are trying to process. Since RAM is very expensive and even most high-powered computers can't be configured with more than 512GB without going into much more expensive server machines, this would limits our ability to process datasets that are larger than the available RAM.
To better explain why RAM is important, let's consider the simple case of a Mean denoising filter.
Noise is a common problem in imaging, and a simple way to minimise the effect of noise is to consider the value of individual pixels within the context of their immediate neighbourhood.
If we look at this group of pixels:
The pixel in the center is clearly a lot brighter than most of the pixels around it. To soften the effect of noise we can look at each pixel in term, group it with the pixels immediately around it, and change its value to that of the mean of the group. If we do this for all the pixels in the image we've applied a Mean filter.
The way the computer processes this is to load these pixels together in the memory and we call this a kernel. We process the kernel, and store the mean value into the central pixel. However, if we were to modify the existing kernel we would affect how the next pixel is changed and the effect would compound throughout the image. Instead we write this pixel into a new image and we repeat the process for the whole image, loading each kernel and writing the output into a new pixel in the destination image.
Normally, the image we're working on is stored on the hard disk, and reading from a hard disk is slow compared to reading from the memory, so typically we would load the whole image in memory and then process each kernel one at a time, progressively building up the output image which we also keep in memory. This means we would need at least twice as much memory as the data we're trying to process, not including the memory required just for the computer to function.
However, as mentioned above, RAM is expensive compared to hard disk storage. RAM is typically 10x more expensive per GB compared to even a very fast SSD and 100x more expensive than spinning disk drives. If we want to process a 1TB dataset using traditional methods we would need 2TB of RAM which would cost 10s of thousands of euros, whereas we could store this dataset on a fast SSD for a few hundred euros instead.
To this end, arivis is built to process images in small blocks, one at a time, and stitching the results together into a temporary document that is stored on the hard disk. This is done while taking care to adequately handle block sizes and overlap to avoid running out of memory or affecting the accuracy of the processing operation.
Typically this results in arivis loading around 2GB of data into the RAM at a time, processing the information in that block, and writing the results to the hard disk.
Some processes, like image filtering, which use a pixel's neighbourhood to affect the results (e.g. denoising, morphological filters, filter based segmentation) will process the blocks with a margin of overlap between blocks equivalent to the radius of the filter to ensure that the results are not affected by the blocking process. Furthermore, we limit the size of most filtering kernels to a maximum diameter of 256 pixels so that we can process blocks that are small enough for most computers, without needing excessive double processing of the data on the edges of the blocks.
So when we look at the Task Manager while executing a pipeline, we might see the memory usage increase by about 2-4GB, and disk usage spikes every time we write the results of the current block and load the next one.
Note that if we look at the CPU core usage, some operations as so fast in the individual task that the refresh rate of the Task Manager window may only show 50% CPU usage. Typically, this means we are using 100% of the CPU, but only 50% of the time while we wait to load and unload data.
Note also that while arivis uses parallelisation wherever possible to speed up processing, not all computing tasks can be parallelised, and the Task Manager will reflect that by showing that on occasion only one core is active.