ZEISS Microscopy Knowledge Base
Help
ZEISS Microscopy Knowledge Base

Spine Tracer

The Spine Tracer operation is used to detect dendritic spines on a neuron trace. The operation is based on the trace model and requires a trace object as input.

Spine Tracer: AI-assisted; Traces Neurite Tracer; Channel #1; Max spine 2 µm; Head threshold 60%; Head size 0,5–2 µm

Spine Tracer parameters

Parameter

Description

Method

Sets the method for tracing spines. Each has a set of settings which need to be properly adjusted to get the best result.

AI-assisted

This method uses a pre-trained Deep Learning Model (DeepD3) to detect spine heads and then trace them to the neurite.

In details, the deep learning model processes the intensity channel to create a probability map of the spines on which the spine heads will be detected. The intensity data is then used to connect the found spine heads to the trace by going along the neck.

Use Segments

This method uses segments created by a previous operation as spines (e.g. Blob Finder, Deep Learning Segmenter or imported in the pipeline via Import Document Object Operation).

The provided objects are not modified by this operation or connected to the trace. Instead, they are used as starting points for the spine tracing to create new approximations of the spines. The intensity data is then used to connect the provided spine heads to the trace by going along the neck..

Use Probability Map

The method is very similar to the AI-assisted method, but instead of using the built-in deep learning model to create the probability map, you must provide a pre-calculated probability map. A probability map can be created with an Image Processing operation, for example Machine Learning Probability or Deep Learning Reconstruction.

Input

 

Traces

Select an already existing neuron or neurite traces of a preceding Operation, e.g. Neuron Tracer or Import Document Objects to which the spines will be connected.

Channel/ Trace channel

Sets Intensity data where neurons and spines (necks) are visible.

Note: Trace channel is only available if Use Segments and Use Probability Map is selected.

Spine Segments

Sets segments representing the spine heads to be connected to the traces. The segments can be created with any of preceding operations or imported.

Note: Spine Segments is only available if the Use Segments method is selected.

Probability map

Sets pre-calculated image data of the spine heads (probability Map). The image should have high intensity values where the spine heads are. A probability map can be created with an Image Processing operation, for example Machine Learning Probability or Deep Learning Reconstruction.

Note: Probability map is only available if the Use Probability Map method is selected.

Parameters

 

Max. spine length

Sets the maximum distance from the spine head center to the trace along the neck. Spines that are longer are discarded.

Note: Increasing this parameter will increase the runtime since a larger area is scanned for spines.

Note: You can use the MeasurementsBright magenta irregular blob with surrounding yellow, cyan, blue, green and purple blobs on black background tool to determine the value.

Additional Parameters

Additional settings for the Spine Trace Segmenter expand when you click Two dark downward chevrons inside a small light-gray rounded square iconin the operation.

Parameter

Description

Head threshold

Sets Threshold to detect the spine heads on the probability map found by the deep learning model used.

Note: Higher values will result in fewer voxels being classified as spines and vice versa. This does not necessarily mean that lower values result in more spines, since two small spine heads can be merged into one by reducing the threshold, if they are close enough.

Note: Head threshold is only available if AI-assisted and Use Probability Map is selected.

Max. overlap

Sets max limit of overlap for the segments with the trace. Segments that have more overlap with the trace are discarded.

Note: Max. overlap is only available if the Use Segments method is selected.

Head size range

Sets the range by size of spine heads to be connected to the trace. Heads that do not fit into the range are discarded.

Note: Head size range is only available if AI-assisted and Use Probability Map is selected. For Use segments it is possible to use before Operations like Object Feature Filter.

Note: You can use the MeasurementsBright magenta irregular blob with surrounding yellow, cyan, blue, green and purple blobs on black background tool to determine the value.

Impressum
Carl-Zeiss-Strasse 22
73447 Oberkochen
Germany
Legal