Creating and Training an Intellesis Segmentation Model
For a good training result always note the following:
- The more accurately you perform the labeling the better the result will be. You can start with only a few annotations and then check the result for problematic areas where you should add more labels to refine the labeling.
- Fewer, more precise labels result in more accurate models than numerous imprecise labels.
- Take care to also label some areas which contain edges of objects and transitions between two classes.
- Adopt an iterative approach: review segmentation and training outcomes before labeling large quantities of pixels.
- Try to label roughly the same amount of pixels per class.
- Do not label very large homogenous areas.
- You have licensed the AI Toolkit and activated it under Maintenance > Toolkit Manager.
- Docker Desktop is installed together with the segmentation container and running.
- You are in Manage Templates.
- In the Show dropdown list, select Intellesis Segmentation Models.
- All existing segmentation models are displayed.
- In the top right tool bar, click
.
- The user interface for training opens.
- In the top left corner, click Import Images. To open an image from the archive, click Import from Archive.
- A file browser or the archive browser opens.
- Select the image for training and click Open. When loading the image from the archive, select the image and click OK.
- If the image contains more than one channel, the Select Channel dialog opens.
- For Training Mode, select either Single Channel or Multispectral. In case of single channel, select the channel you want to use for training. Otherwise, all channels of the image will be used for training the model.
- Training mode and channel are selected.
- Click OK.
- All images you import need to have the same channel structure and pixel type of the initially imported image. When importing multiple images, the channel selection applies to all images.
- The image is added to the list. Note that all imported images are included in your training model.
- If you have imported an image from the archive, it is copied to the location defined under Maintenance > General Options > Intellesis.
- Select the image in the list.
- The image is displayed in the Center Screen Area. Note that you can always add more images to refine the training via Import Images.
- Define the classes based on your image and segmentation goals. You can specify the number of classes needed for your task. When initiating a new model, two predefined classes (Object and Background) are available by default. Add as many classes as you need for your segmentation by clicking Add Class.
- You have created the classes that you want to distinguish.
- To rename a class, right click on the entry, select Rename, enter a new name and click
. Alternatively, double click the name entry, enter a new one and click
, or press Enter. Note that you must not use the name Root for one of your classes as this a reserved keyword from the image analysis.
- Now move the courser inside the image and start labeling the areas which you want to assign to the selected class. To label within the image simply press the left mouse key and move the mouse.
- After labeling a few areas with different classes, click Train & Segment.
- The software starts the training. The system tries to automatically recognize other areas of the same class. Depending on the image, the pixel classification can take a while. When finished the image has the additional channel Seg(menation) containing the segmentation preview.
- If you are not satisfied with the result, you can label more details of the corresponding classes. Therefore, you can zoom into the image or change the brush size of the curser. The more accurately you label the different classes within the image, the better the recognition will be. When you have finished the labeling, you have to click Train & Segment again. You can repeat that process until you are satisfied with the segmentation result.
Note that at this point as a result you only see a pseudo segmented image and only the area visible in the main window is segmented (max. area 5000 x 5000 px). For full segmentation of an image or data set, use the model in the Intellesis Segmentation tool for image processing, see Using an Intellesis Segmentation Model for Image Processing.