TCA

The following microscopes are supported:

  • Axioscope 7 and SteREO Discovery.V8
  • Axio Imager 2
  • Axio Zoom.V16

Minimum System Requirements

ZEISS Microscopy Workstation Compact (HP Z2 G1i)

Recommended System Requirements

ZEISS Microscopy Workstation Premium (HP Z8 G5)

Intel® Core® Ultra 7 processor, 265K with 20 cores, 3.9 GHz clock frequency

Intel® Xeon® W5-3425 (3.2 GHz, 30 MB cache, 12 cores)

Recommended in combination with ZEN Toolkit AI: Intel® Xeon® W7-3455 (2.5 GHz, 67.5 MB cache, 24 cores)

128 GB RAM

128 GB RAM

Recommended in combination with ZEN Toolkit AI: 256 GB RAM

Graphic card

NVIDIA RTX A1000 8 GB or

NVIDIA RTX PRO 4000 24 GB

In combination with ZEN Toolkit AI the recommended system requirements represent the minimum PC hardware configuration, see Microscopy Workstation Premium (HP Z8 G5).

Graphic card

NVIDIA RTX PRO 4000 24 GB DP

Recommended in combination with ZEN Toolkit AI: Graphic Card NVIDIA RTX Pro 4500 32 GB DP

Hard drive

1 x SSD 1 TB M.2 NVMe (system)

1 x HDD 12 TB SATA 7200 rpm or

2 x HDD 12 TB SATA 7200 rpm (data)

Hard drive

1 x 2 TB M.2 NVMe (system)

2 x 12 TB SATA 7200 rpm (configured as 10 TB RAID 1 hard drive)

Recommended in combination with ZEN Toolkit AI: RTX pro 4500 mit 32 GB RAM

Ports

1x PCI Express Generation 5x16

1x PCI Express Generation 4x4

1x PCI Express Generation 4x1 3 x M.2 Slot

Ports

2x PCI Express Generation 5x16

1x PCI Express Generation 5x4

2x PCI Express Generation 4x16

2x PCI Express Generation 4x4

1x PCI Express Generation 3x8

4 x Type-A SuperSpeed USB 10 Gbps

2 x Type-C SuperSpeed USB 20 Gbps (front)

3 x Type-A Hi-Speed USB 480 Mbps

2 x Type-A SuperSpeed USB 5 Gbps

2 x Type-A SuperSpeed USB 10 Gbps (rear)

2 x USB 3.2 Gen2x2 type C (front)

8 x USB 3.1 Gen 1 type A (2 x front, 6 x rear)

Microsoft® Windows® 11 Enterprise, LTSC 2024 x64.

The user must be logged in with at least user privileges. For the software installation procedure local administrator rights are required.

Microsoft® Windows® 11 Enterprise, LTSC 2024 x64.

The user must be logged in with at least user privileges. For the software installation procedure local administrator rights are required.

NMI

The following microscopes are supported:

  • Axio Imager 2
  • Axio Observer 7 Materials
  • Axiovert 7

Minimum System Requirements

ZEISS Microscopy Workstation Compact (HP Z2 G1i)

Recommended System Requirements

ZEISS Microscopy Workstation Premium (HP Z8 G5)

Intel® Core® Ultra 7 processor, 265K with 20 cores, 3.9 GHz clock frequency

Intel® Xeon® W5-3425 (3.2 GHz, 30 MB cache, 12 cores)

128 GB RAM

128 GB RAM

Graphic card

NVIDIA RTX A1000 8 GB or

NVIDIA RTX PRO 4000 24 GB

Graphic card

NVIDIA RTX PRO 4000 24 GB DP

Hard drive

1 x SSD 1 TB M .2 NVMe (system)

1 x HDD 12 TB SATA 7200 rpm or

2 x HDD 12 TB SATA 7200 rpm (data)

Hard drive

1 x 2 TB M.2 NVMe (system)

2 x 12 TB SATA 7200 rpm (configured as 10 TB RAID 1 hard drive)

Ports

1x PCI Express Generation 5x16

1x PCI Express Generation 4x4

1x PCI Express Generation 4x1 3 x M.2 Slot

Ports

2x PCI Express Generation 5x16

1x PCI Express Generation 5x4

2x PCI Express Generation 4x16

2x PCI Express Generation 4x4

1x PCI Express Generation 3x8

4 x Type-A SuperSpeed USB 10 Gbps

2 x Type-C SuperSpeed USB 20 Gbps (front)

3 x Type-A Hi-Speed USB 480 Mbps

2 x Type-A SuperSpeed USB 5 Gbps

2 x Type-A SuperSpeed USB 10 Gbps (rear)

2 x USB 3.2 Gen2x2 type C (front)

8 x USB 3.1 Gen 1 type A (2 x front, 6 x rear)

Microsoft® Windows® 11 Enterprise, LTSC 2024 x64.

The user must be logged in with at least user privileges. For the software installation procedure local administrator rights are required.

Microsoft® Windows® 11 Enterprise, LTSC 2024 x64.

The user must be logged in with at least user privileges. For the software installation procedure local administrator rights are required.