Difference in Job Mode

The available functionality of the individual steps can differ between the wizard in Free Mode and the steps that can be added in Job Mode, e.g. the Interactive checkbox is not visible in Job Mode.

In this step you can post-process the segmented objects interactively. You can modify the results of the automated segmentation when you analyze your image data. Note that during the setup of the analysis (via Setup Image Analysis in Free Mode), the segmentation is only performed on the area visible in the viewport. If you enter the interactive analysis or are in Job Mode, the image will be fully segmented.

Parameter

Description

Interactive

Not available for Technical Cleanliness Analysis.
Activated: The segmented objects can be post-processed interactively while the analysis setting is run.

Class List

Not available for Technical Cleanliness Analysis.
Selects the class whose objects you want to process.

Edit Region section

Parameter

Description

Draw

Enables you to draw new objects of the selected class.

Erase

Enables you to erase parts of an object. While pressing the left mouse button, outline the parts of the object that you want to erase. Right-click to erase these parts of the object.

Cut

Enables you to separate connected objects. While pressing the left mouse button, draw in the separation line between the objects. Right-click to cut the objects.

Merge

Enables you to connect objects. While pressing the left mouse button, outline the parts of the object that you want to merge. Right-click to merge the objects.

Fill

Fills a hole. To fill a hole, left-click on the hole. If a selected object completely surrounds another potential area, then the enclosed area is also included ().

Remove

Enables you to remove a drawn in object by clicking on it.

Remove All

Deletes all drawn objects.

Draw Rectangle

Enables you to add a rectangular object or cut a rectangular region from an object.

Draw Circle

Enables you to add a circular object or cut a circular region from an object.

Draw Contour

Enables you to add an object or cut a region from an object.

Draw Contour (Spline)

Enables you to add an object or cut a region from an object.

Draw Active Contour

Enables you to add an object or cut a region from an object.

Draw Polyline Region

Enables you to add a line-object.

Draw Point

Enables you to add a point object.

Region Growing section

For the module Technical Cleanliness Analysis, only Undo and Redo are available.

Parameter

Description

Mode

Expands or reduces the size of an object based on the brightness of surrounding pixels

–

+

Click on areas in the image you want to add to the selected object class.

–

-

Click on areas in the image you want to remove from the selected object class.

Intensity

Sets the tolerance value for the intensity. The tolerance value specifies how much the intensity of a pixel may deviate from the average intensity of the selected object in order to still "grow" to become part of the object. A higher value means that more pixel values similar to the selected one are included. A lower value means that only the exact pixel value selected is included.

Color

Only active if your input image is a color image.
Sets the tolerance value for the color. The tolerance value specifies how much the color value of a pixel may deviate from the average color value of the selected object in order to still "grow" to become part of the object. A higher value means that more colors similar to the selected one are displayed. A lower value means that only the exact color selected is displayed. The comparison is based on the RGB (red green blue) colorspace.

Fill

Fills holes that are created during region growing.

Activated (): If a detected object completely surrounds another potential area, then the enclosed area is also included.
Deactivated (): Only the detected object is included.

Undo

Undoes the last action.

Redo

Restores the last undone action.

Post Processing section

Only visible for images with a size smaller than 10000 x 10000 pixel.

Parameter

Description

Region Filter

Reapplies the region filter you defined in the previous step to the post-processed image.