Data Results
You can view the analysis results in automatically generated results, for example tables. You can check the following results in Browse Results in the Result Documents area.
For opening tables, see Opening Selected Results in the Viewer.
Legend for the placeholders:
- <Loop No>: Indicates the loop iteration in which the specimen analysis was performed. For a single sample, the loop number is 1, for multi samples, the numbering is incremented: loop no. = n.
Applied Parameters
This table informs you about the acquisition parameters of microscope and camera and additional parameters to reproduce the analysis result.
Particle Revision Table
This table informs you about particle revision steps (change of type, combine, cut, edit) that you have made in the Size Distribution view, see Changing Particle Type.
Results Statistics Table
This table informs you about the values of the Statistical Analysis in the Size Distribution view, see Statistical Analysis Tool.
Classification Table Particle Length <Standard> <Image no.>
This table informs you about the particle size distribution based on the selected length classification parameter displayed in the Size Distribution view in the Length Class Table, see Class Chart - Length Class Table.
Classification Table Particle Width <Standard> <Image no.>
This table informs you about the particle size distribution based on the selected width classification parameter) displayed in the Size Distribution view in the Width Class Table, see Class Chart - Width Class Table.
Calculation Table Illig Value <Standard> <Image no.>
This table shows the calculation of the Illig value, see Understanding the Illig Method. It is also displayed in the TCA report for component cleanliness analysis.
ParticleDocument <Image no.>
This document opens an inspection view identical to the Size Distribution view to inspect particles, see Inspecting Results. Here, you cannot modify the results.
ParticleTable_Specimen <Image no.>
This table informs you about each individual particle with all relevant measurement results.
<xy>-Loop-<Image no.>
This image includes the analysis results considering particle revision results.
ZEISS Form Technical Cleanliness-<No.>
This form displays the TCA input form, see Form Workbench.
TCA Report <No.>
This report displays general and global information as well as the presentation of the results, see Reports.
Equivalent Particle Area Table <Standard name> - <No.>
This table shows the calculation results of the equivalent total particle area, if activated in the job template, see Equivalent Particle Area (Components) Tool.
ON THIS PAGE
- Data Results
- Applied Parameters
- Particle Revision Table
- Results Statistics Table
- Classification Table Particle Length <Standard> <Image no.>
- Classification Table Particle Width <Standard> <Image no.>
- Calculation Table Illig Value <Standard> <Image no.>
- ParticleDocument <Image no.>
- ParticleTable_Specimen <Image no.>
- <xy>-Loop-<Image no.>
- ZEISS Form Technical Cleanliness-<No.>
- TCA Report <No.>
- Equivalent Particle Area Table <Standard name> - <No.>