Analysis Results View
When you open a selected analysis run, the specific view displays the images of the run in a dedicated view layout:
|
1 |
Menu Bar Here you can switch to the different main views, see Menu Bar. |
|
2 |
Analysis Run Image List Displays the images of your analysis run. The tool bar above the list offers functionality like selecting which columns to display and their order, see Result List Tool Bar. The status column displays the state for the individual image. You can resize the list to have more space allocated to the image viewer, and have a context menu for each individual entry, see Result List Context Menu. Each entry provides a list of all sub-images for each image. For wellplates, it follows a hierarchy: Image (plate) > well > field. For all others it is image > sub-image. If you have selected a single image, it is displayed in the image viewer to the right. |
|
3 |
Image Viewer If you have selected a single image in the list, the image is displayed with the standard image viewer and the respective controls, see User Interface Image Viewer. You can also view your segmentation results in the viewer. |
|
4 |
Heatmap Displays a heatmap of the analysis results for each well. With the drop-down you can select which Feature is visualized. This view option is only visible if the Aggregate Features operation is in the analysis pipeline and you have performed the analysis on a well plate image. The selection from the Analysis Run Image List, Heatmap, and entries in the tables of the Result Tabs are synchronized. Clicking on a well in the heatmap will select the respective entry in the currently selected result tab, image list, viewer, and vice versa. |
|
5 |
Result Tabs Displays the two tabs Well-Level Results and Field-Level Results, where you can see the analysis results for the well or field level. These view options are only visible if the Aggregate Features operation is in the analysis pipeline and you have performed the analysis on a well plate image. The entries are synchronized with the heatmap, image list, and image viewer. |
|
6 |
Information Panel Here you can show or hide the Information panel which displays information about the respective item. The information is grouped into different expandable/collapsible sections, including dedicated sections for information about the analysis run and the used pipeline, see Information Panel. |