Pipeline operations layout

The following operations are part of the pipeline.

Input ROI

This operation allows to select the region of interest (ROI). ROI defines the dataset subarea that will be processed and analyzed by the pipeline.

Input ROI parameters

Parameter

Description

ROI

Sets the processing and analysis target space.

Current View

The selected Z plane and the viewer area are processed.

Current Plane

The selected Z plane is processed (XY).

Current Time Point

The selected time point is processed (XYZ).

Current Image Set

The complete dataset (XYZ and time) is processed.

Custom

Allows to mix the previous methods.
Note: Use the Custom option during the pipeline setting and testing. Set a sub volume (XY, Planes, Time Points, channels) of your dataset on which perform the trial. This will speed up the setting process.

Channels

Sets the processing and analysis target channels. Selecting a single channel, all the operations in the pipeline will be forced to use it.

Scaling

Sets the scaling of the dataset, which reduces it size. The measurements will not be modified by the scaling factor

Crop input data

Sets the limitation of the data used for the calculation to only the cropped selection defined above. If this option is not selected, the entire image set is used for the calculation.

Additional Parameters

Additional settings for Input ROI expand, when you click in the operation.

Parameter

Description

Bounds

Sets the analysis area edges. The whole XY bounds, the viewing area or a custom space can be applied.

Planes

Sets the analysis planes range. A single plane, a range of planes or the whole stack can be selected.

Time Points

Sets the analysis time points range. A single time pint, a range of time points or the whole movie can be selected.

Object Feature Filter

Allows the segments filtering based on multiple parameters selection.

Object Feature Filter parameters

Parameter

Description

Input

Sets the filter input. If more than one segment operation is present in your pipeline, the correct input source must be set.

Is of type

Sets the type of filter which filters the objects based on the selected type. By default, it is set on Any for all object types. The list of available features is updated accordingly.

Filter selection

Sets the function for the segmentation is performed.

Criterion Settings

These parameters depend on the selection of the filter.

+ Add Filter

Allows to add a Simple, Ratio or Tag filter criterions.

Store Objects

Store the detected segments (tag) in the active dataset.