This article explains how to export movies from images in arivis Pro.
This article explains how to export movies from images in arivis Pro.
As we can see above, the Movie Export function can be a fast and effective way to create an animation. However, it is very limited by the types of transition and effects we can apply to images. Also, for datasets with a lot of depth a volumetric rendering animation can be much more effective at communicating spatial relationships, and using clipping planes and object display transitions can make it easier to understand the relationships between objects. As a whole, volumetric rendering animations can create a much more powerful impression of the image and analysis.
Clicking the Export button above opens the Storyboard Movie Export window where we can configure our export options.
Unlike snapshots and HD image exports that can normally be stored in memory for easy copy & paste into an output destination (e.g. PowerPoint presentation), movies are generally much larger and therefore need to be written to the hard disk and so the first options we find relate to the save location and name. The save location and name are completely up to you (the default is to save the movie with the same name as the original file in the same folder as the dataset). For the video format we need to consider where the video will be shown. Generally most modern devices support the H264 format and it is our recommendation. It is also a good format for importing into video editing software if we want to splice our arivis video with other footage, but some older systems may not support it and MPEG4 may be more suitable in such cases.
After the file saving settings we have the movie video output options. These can make a significant impact on the quality of the video output and the time required to create it.
Generally speaking, the higher the quality of the video the longer the movie export will take.
The Video Resolution setting affects both the size of the output file and the quality of the output. Here the the way the video will be presented will be quite important. If we include the video in a PowerPoint presentation, using the XGA or HD (720p) options are usually fine, especially if the video does not take the entire slide. If we export it for full screen viewing then Full HD (1080p) up to Ultra HD (4K) may be preferrable, but we should remember that the time it takes to render the video will increase significantly, and so will the output file size, for what may appear to be only a marginal gain in image quality in many cases. For example, going from 1080p to 4K will typically double the rendering time. arivis also support 360 video outputs which can be quite interesting in some cases, but requires viewers that support this format and some user interactivity to set the view angle when playing back the video.
The frame rate affects how smooth the video playback can be. Low frame rates (below 24FPS) can appear a little jerky, while 25-30FPS is the standard for most videos. Using 60FPS can appear smoother, and is recommended for 360 videos, but some video players won't be able to play back these high framerates smoothly resulting in noticeable jumps as the media player lags and then catches up to the required framerate. The most important thing to note is that going from 30FPS to 60FPS will require at least twice as much time to process the video and will result in a file that is about twice as large.
Generally, we recommend using a low video resolution and framerate (720p at 25FPS) to produce a video quickly, and switch to high resolution and higher framerates only on occasions to really showcase data only as needed.
This setting is mostly related to how the software handles large datasets. By large datasets we mean datasets for which a single timepoint cannot easily fit in the video memory of the GPU.
Viewing data in 3D and rendering videos are both highly dependent on the GPU. We cover the topic of how arivis handles large data in the 4D viewer in this article, but in short, since most GPUs have a finite amount of video memory available and a finite ability to render 3D datasets within a given amount of time, arivis typically down-samples data to make possible to render quickly in 3D. This down-sampling can lead to a noticeable drop in in the level of detail we can render and can also lead to noticeable down-sampling artefacts. As we explained in this article about rendering HD screenshots, it is always possible to render both screenshots and videos with the highest level of details, but for large datasets this comes at the cost of high processing times.
The data resolution slider adapts both to the PC configuration and to the dataset.
The scale goes from 64MB of VRAM usage on the left to the full resolution of the dataset on the right, and each graduation mark typically represents a doubling of the memory usage.
Note that since the 3D viewer renders 8bit version of the images the VRAM requirement may be significantly smaller than the actual dataset. Also, since we can only render one timepoint in any given frame, the amount of memory required is limited by the amount of data in a single timepoint.
The colour coding reflects the hardware configuration. The green part of the scale represents the amount of VRAM available on the GPU. Sticking to the green part of the scale reduces the loading times and also leads to much faster renders.
Since most computers typically have more system memory that video memory, we can use this as temporary storage for the image data instead, up to the amount of system memory available. The loading time is usually comparatively faster because loading 1MB from the disk in the RAM is usually faster than loading that data in the VRAM, but the rendering time suffers because the GPU is now reading data from the RAM rather than the faster and closer VRAM.
But since some datasets can be larger than even the RAM available, arivis also allows creating high resolution videos even at native resolution by using a hybrid rendering approach, though this is done at the cost of rendering time.
If we are rendering a very large dataset, it is recommended the minimum amount of data resolution required to see the detail that we need to see. Some experimentation using HD screenshots may be worthwhile to find out what those optimal settings might be. It may also be worth considering splitting the animation into several movies and using volume clipping to narrow down the rendering to specific regions of interest for the high level of detail required and then, if necessary, merging the movies into a single file using video editing software.
None of the options above can be used for recording application processes like object creation, pipeline execution, and other image or object modifications. However, as mentioned above a picture is worth a thousand words and a movie even more so. Sometimes it is easier to create movies to explain the process. In such cases it is better to use screen recording software to create these movies. Some basic screen recording software do not feature video editing tools but the movies can be imported into video editing tools. Several screen recording software exist that include movie editing options with advanced features. An example of this can be seen above where we used screen recording software to record the process of generating and exporting the storyboard.