ZEISS Knowledge Base
Help
ZEISS Knowledge Base

arivis Network License setup

Introduction

As described in this article on general software activation, arivis Vision4D is protected by a 3rd party license management software. This license management is based around the concept of keys that grant users access to the software and specific features thereof. The key or license can come in a 2x2 major distinctions.

First, licenses can be either

  • Soft licenses (SL) use software keys that are generated from, and attached to, a specific computer, or
  • Hard licenses (HL)  which have the keys embedded in a USB "Dongle" that can be manually moved from machine to machine as needed

And in either of those cases, the license can also be

  • Fixed, where the license is only available on the machine where it is located, or
  • Floating (network), where the license is attached to a specific computer but distributed out  to clients on the same network

Hard keys do not require activation as the license is already activated on the dongle when shipping, but soft licenses must be activated to lock the key to the user's computer. Network licenses need only be activated once, on one computer, which from then on serves as the license server. Floating licenses may require some additional configurations on both servers and clients to permit the distribution of the license (see below).

Selecting a License server

The first and most important thing to note with network licenses is that the license server is a single computer. Once activated that one machine can serve multiple clients.

That computer doesn't need to be a Server in the typical sense of the term, but it should definitely be a computer on the same network as the clients and it should preferably be a computer that can be left on so that clients are always able to access it. In that respect, putting the license server on a server computer is usually preferable.

The license server computer does not need to be able to run arivis Pro/Vision4D, it just needs to be able to run the license distribution tool. The License Server can be installed on either Windows or Linux machines.

Virtual machines should be avoided as changes to the VM can irreversibly invalidate the license. Support related to licensing invalidation due to VM changes may be chargeable.

Network Configurations for Floating Licenses

The license server broadcasts available licenses on the network to which it is connected for clients to see when arivis Pro Vision4D is started. This broadcast is done through a specific network port, which must be open on both the server and clients. Please ensure that port 1947 is open for TCP/IP on any firewall on both the server and client computers. You can test that the port is open using telnet to ping that specific port. To do this, open the command prompt on the client computer and type the following command (Telnet may need to be enabled in the windows settings, other ping tools that enable the use of a specific port can be used): 

telnet <address> <port_number>

If the ping does not work, please contact your IT support team.

Clients must have direct access to the IP address of the machine on which the license is kept. The broadcast mentioned above is only available within the local network. For machines outside the server's local network a VPN may be required, or at the very least the sentinel control center should be configured to point directly to the IP address of the server machine. Please see below.

Additional License Management Tools

The License Tool allows the user to do several things, like activating or transferring license, but some additional options are available to check the license status, monitor license usage, or limit who can access the license. In either Windows or Linux machines, these additional tools can be accessed by opening a web browser and entering this address:

http://localhost:1947

Here, users can use the links on the left to check the status and validity of all licenses available on the current computer, check the access log to monitor usage, and use the Configuration tools to instruct a machine to actively seek or block connections for specific IP addresses.

Aggressive search for licenses

In normal circumstances, as long as both the client and server are on the same network and the correct port firewall exceptions have been configured, the clients should automatically see and be able to use the licenses if any are available. However, if the above have been checked and the clients are still unable to see the license we can set up an aggressive search to force the client to query the license on a specific IP address.

As with limiting access, we start by going to the Configuration menu in the Sentinel admin control center, but then go to the Access to Remote License Managers tab.

Here we can check the box for "Aggressive Search for Remote Licenses" and also enter the IP address of the license server machine. 

Note that if the IP addresses are assigned dynamically this can result in the aggressive search failing since the IP address the client is searching on might have been reassigned to another machine. It is therefore important to make sure that the static IP addresses are used.

Conclusion

In most cases, network license configurations are relatively quick and easy, but if you have issues accessing the license, please check our troubleshooting article for more information or use the downloadable version of this article below which also contains more details.

Download the "Vision4D Network License setup" PDF

Impressum
Carl-Zeiss-Strasse 22
73447 Oberkochen
Germany
Legal