The Volume Fusion module for Vision4D has been available since 2017. This article explains how it can be used.
The Volume Fusion module for Vision4D has been available since 2017. This article explains how it can be used.
Volume Fusion was added to Vision4D as a tool to merge multiple image volumes that could not be merged otherwise. There are several reasons why two image volumes could not be merged:
Volume Fusion has been designed to work around these limitations.
This enables a few specific applications which would otherwise not be practically possible, including for example:
In all of these cases, and more, Volume Fusion can be used to generate a single volume from two separate volumes, and that fused volume can be used for analysis and visualisation like any other dataset.
While volume fusion can work with images of different dimensions, the images must be of the same bit depth. Bearing in mind that higher bit depths lead to larger file sizes, it may be preferable to scale down higher bit depth images to match a lower bit depth volume than the other way around. Bit depth scaling is done through the Transformation Gallery (Data> Transformation Gallery).
If both images have the same bit depth no scaling is necessary.
Registering using landmarks considers the image spatial calibrations to work out the scaling required (registering using surface transformations ignores calibrations in favor of the user-defined scaling). This is usually not an issue when fusing images captured using the same microscope and the same magnification. However, if the two volumes are imaged using different imaging devices the calibrations could be different and this could lead to the fused volumes having a scaling offset. Also, when doing multimodal imaging where the sample may receive additional preparation steps for the second acquisition, the sample can shrink or grow resulting in a calibration that is technically correct, but effectively wrong. In such cases, we can either correct the calibrations to account for changes in the sample or use the surface transformation to disregard the calibration and adjust the scaling as required.
Each time we do a volume fusion we create a new image set. The typical destination for this new set is the same SIS file where the original sets currently reside. This means that when we fuse images, the size of the SIS file will grow significantly because it will now include both the original sets and the fused volume, which is usually about at large as the sum of the two original sets. So, if we merge a 1GB set, with another 1GB set, the resulting file will likely be in the region of 4GB (1GB for the base set + 1GB for the moving set + 2GB for the fused volume). Because of this, and the fact that the base and moving sets are generally only useful for the creation of the fused volume, many users will prefer to output the fused volume as a new SIS file and then delete the SIS file containing the original sets when finished.
However, as mentioned above, we can only fuse volumes that are in the same SIS file, so what would be the best way to fuse 3 or more sets together? Let us consider a case where we might merge 4 separate image sets into a single fused volume. We would start off by importing all of them as multiple sets in the same SIS file containing "set-1", "set-2", "set-3", and "set-4". We would then fuse "set-1" and "set-2" into our first fused volume, "fused-set-1". We can then do the fusion between "set-3" and "set-4" to create "fused-set-2". Finally, we would fuse "fused-set-1" and "fuse-set2" into a new "fused-set-all". The final result can be saved in a new SIS file, but all the intermediate steps must be created in the original SIS file.
Additionally, users should consider the point above concerning the size of the SIS file after fusion. If again we assume each set is 1GB, the SIS file will grow to around 8GB before we do the final fusion into a new SIS file that will only be around 4GB. So in total, we would need at least 16GB of spare disc space to store all the images, at least until we have finished and we can delete the original and interstitial images. Of course, the actual size of images users might wish to fuse will vary, but care should be taken to ensure there is enough storage space not just for the original images and the end results, but also for the intermediate steps.