With this dialog you can open images or ZEN Connect projects saved in the ZEN Data Storage.
|
1 |
Stored Data |
|
2 |
Image Preview |
|
3 |
Image Control Section |
With this dialog you can open images or ZEN Connect projects saved in the ZEN Data Storage.
|
1 |
Stored Data |
|
2 |
Image Preview |
|
3 |
Image Control Section |
|
Parameter |
Description |
|
|---|---|---|
|
Search |
Searches the database for the term entered in the text field. |
|
|
Tags |
Opens an input field to filter images based on their tags, see Filtering Connect Projects and Images in ZEN Data Storage. |
|
|
– |
Search Field |
Searches the image tags for the input of this field |
|
– |
Or |
Activated: Applies a logical Or operator if multiple tags are selected in the list below and filters for all images that contain at least one of the selected tags. |
|
– |
And |
Activated: Applies a logical And operator if multiple tags are selected in the list below and filters only images that contain all selected tags. |
|
– |
Tag List |
Displays all available tags. Filters the documents in ZEN Data Storage based on the activated tags of this list. |
|
– |
Clear |
Clears all filter criteria for tags. |
|
|
Displays a filter panel with metadata, see Filtering Connect Projects and Images in ZEN Data Storage. |
|
|
File Dropdown |
Selects which files are displayed in the table below. If you have access to collections, they are also displayed as an option in the dropdown, see Creating a Collection for Data. |
|
|
– |
All Files |
Displays all accessible data. |
|
– |
My Files |
Displays only my images or projects. |
|
– |
Files Shared With Me |
Displays all files that are shared with me, including public images/projects. |
|
Document Table |
Displays all available images or ZEN Connect projects and information about them. The table entries can be sorted according to each individual column. You can customize the view of the table by toggling the visibility of individual columns, see Configuring the Stored Documents Table. The displayed information for the images are extracted from the image metadata. If you have configured ZEN Data Storage to extract custom metadata, they can also be displayed as columns. For information about configuring custom metadata, see the installation guide of ZEN Data Storage. Additional functionality for the images or projects is provided by an extra right click menu, see Stored Documents Right Click Menu. |
|
|
– |
Preview |
Displays the preview of the image. |
|
– |
File Name |
Displays the file name and the format of the image. You can sort the file names alphabetically. |
|
– |
Original File Name |
Displays the original file name in case you have uploaded the image as a third party image with the ZEN Data Storage Uploader. |
|
– |
File Size |
Displays the file size. |
|
– |
Software Application |
Displays with which software application the image was acquired. |
|
– |
Software Application Version |
Displays the version of the software application. |
|
– |
Created Date |
Displays the creation day. |
|
– |
Last Changed |
Displays at what date the image was last changed. |
|
– |
Shared |
Displays |
|
– |
Comment |
Displays a comment. |
|
– |
Microscope Type |
Displays the type of the microscope. |
|
– |
Microscope Name |
Displays the user defined custom name of the microscope. |
|
– |
System Name |
Displays the system name. |
|
– |
Objective Name |
Displays the name of the objective. |
|
– |
Objective Magnification |
Displays the objective magnification. |
|
– |
Reflector |
Displays the reflector. |
|
– |
Channel Name |
Displays the name of the channel. |
|
– |
Camera Name |
Displays the name of the camera. |
|
– |
Scaling |
Displays the scaling. |
|
– |
Imaging Light Source Name |
Displays the name of the imaging light source. |
|
|
Opens the Share and Manage Access dialog to directly share the selected file with a user or group, see Sharing Data Directly With Users and Groups. |
|
|
|
Opens the Add to Collection dialog to share the selected files with a collection, see Adding Data to a Collection. |
|
|
|
Deletes the selected documents from the database. |
|
|
Parameter |
Description |
|
|---|---|---|
|
Z-Position |
Only available for z-stack images. |
|
|
Time |
Only available for time series images. |
|
|
|
Only visible, if the selected image document contains attachments (e.g. a thumbnail, label or preview scans) like for Axioscan images. Selects which image is displayed in the preview area by using the arrows or clicking on the small circles. The small circles also display a tooltip indicating what kind of image it is (e.g. Label). |
|
|
Metadata |
Displays a section with metadata of the selected image. |
|
|
– |
Tags |
Displays and edits tags for the image. For more information, see Adding and Deleting Tags for ZEN Data Storage Images. |
|
– |
Image Metadata |
Displays metadata for the currently selected image. The metadata is synchronized with the displayed columns in the stored data section on the left. |
|
Open |
Opens the image or project in ZEN. |
|
|
Cancel |
Closes the dialog without opening a file. |
|