In this step you can define custom statistical features for your regions or objects.

Parameter

Description

Interactive

Activated: The features can be changed interactively while the analysis setting is run.

Classes List

Selects the class for which you want to define the custom statistical feature(s).

Define Custom Feature

Opens the editor to define a custom statistical feature.

Custom Statistic Feature List

Displays the created custom statistical features.

Name

Displays the name of the feature.

Custom Statistical Feature Editor

Parameter

Description

Custom Features

Displays a list of the created custom features.

Name

Displays the name of the created custom statistical feature.

+
Add

Adds a new custom feature that can be defined with the options on the right side.


Delete

Deletes the currently selected feature.

Define Custom Feature

Name

Defines the name of the feature.

Unit

Specifies the unit of the feature as free text input. This input is optional.

Define Operands

Displays and defines the operands used for the calculation of the feature.

Operand

Displays the name of the operand.

Class

Selects the class that is used for the definition of the operand. For a single region class, also the classes of the children can be selected.

Feature

Displays all available predefined measurement features for the selected class and selects which measurement feature should be used for the definition of the current operand. If you activate the checkbox behind the selection dropdown, the selected feature is also set visible in the result table.

Statistical Operation

Selects the statistical operation used for the current operand, e.g. Mean, Min, Max, Sum and Count.

Expression

Displays the expression of the Operand defined by the Class and Feature selection.

+
Add

Adds a new operand to the list.


Delete

Deletes the currently selected operand.

Define Custom Expression

Defines the mathematical calculation of the statistical feature, using the Operands and mathematical operators, e.g. 100*(a/b+Math.Pow(c,2)).

+

Adds the mathematical operator for summation to the calculation.

-

Adds the mathematical operator for subtraction to the calculation.

*

Adds the mathematical operator for multiplication to the calculation.

/

Adds the mathematical operator for division to the calculation.

Pow

Adds the mathematical operator to calculate the power of a certain base value. Note that this operator requires two input values (the base and power value) separated by a comma, e.g. Math.Pow (2,3), which corresponds to 23.

Sqrt

Adds the mathematical operator to calculate the square root of a value.

Abs

Adds the mathematical operator to return the absolute number, i.e. non negative values.

PI

Adds a mathematical operator for Pi.

Verify Expression

Checks the syntax of the Expression.

OK

Adds the defined custom statistical features and closes the dialog.

Cancel

Closes the dialog without saving the changes.