The TCA module supports the following standards:

Supported standards in TCA module.

Standard

Description

VDA 19.1

Refers to component cleanliness.

For more information, see VDA 19 Part 1; Inspection of Component Cleanliness.

ISO 16232

Refers to component cleanliness.

For more information, see ISO 16232 Road Vehicle. Cleanliness of Components and Systems.

VDA 19.2 (Illig)

Refers to environmental cleanliness. For more information, especially on the Illig Value, see VDA 19.2 Technical Cleanliness in Assembly - Environment, Logistics, Personnel and Assembly Equipment.

VDI 2083, Part 21

Refers to cleanliness of medical products.

For more information, see VDI 2083 Part 21; Cleanroom Technology. Cleanliness of Medical Devices in the Manufacturing Process.

ISO 4406

Refers to oil cleanliness.

For more information, see ISO 4406 Hydraulic Fluid Power. Fluids. Method for Coding the Level of Contamination by Solid Particles.

ISO 4407

Refers to oil cleanliness.

For more information, see ISO 4407 Hydraulic Fluid Power - Fluid Contamination - Determination of Particulate Contamination by the Counting Method Using an Optical Microscope.

GB/T 20082

Refers to oil cleanliness.

For more information, see GB/T 20082 Hydraulic Fluid Power - Fluid Contamination - Determination of Particulate Contamination by the Counting Method using an Optical Microscope.

GB/T 14039

Refers to oil cleanliness.

For more information, see GB/T 14039 Hydraulic Fluid Power. Fluids. Method for Coding the Level of Contamination by Solid Particles.

NAS 1638

Refers to oil cleanliness in the aerospace industry. Cleanliness requirements of fluids used in hydraulic systems.

For more information, see NAS 1638 National Aerospace Standard.

SAE AS 4059

Refers to oil cleanliness in the aerospace industry. Cleanliness requirements of fluids used in hydraulic systems.

For more information, see SAE AS 4059 Revision G Aerospace Fluid Power - Contamination Classification for Hydraulic Fluids.

Particle Test Standard (CC) (2010) Slide D45

Refers to microscope system validation for component cleanliness testing.

For more information, see Particle Test Standard (CC) (2010) Slide D45.

Particle Test Standard (CC with OC) (2010) Slide D45

Refers to system validation with component cleanliness job template with ML object classification.

For more information, see Particle Test Standard (CC with OC) (2010) Slide D45.

For detailed information, check the respective standards.

All supported standards are visible in the Standard Template Editor, see Standard Template Editor. VDA 19.2 (Illig) is an exception, it is provided as individual job template, see Understanding the Illig Method.