In a ZEN Connect project, from the context menu of the image, in the Tree view or with the Context menu button, you can perform several functionalities.

Image

Tree view

Context Menu
button

Zoom to
For more information, see Zooming

X

X

X

Zoom to 100%
For more information, see Zooming

X

X

X

Show/Hide
For more information, see Moving or Hiding Images

X

X

X

Remove Data
For more information, see Removing Data

X

X

X

Rename Data
For more information, see Renaming Data

X

X

X

Align Data
For more information, see Activating the Alignment Process

X

X

X

New Session
For more information, see Starting a New Session

X

Clear Alignment
For more information, see Clear Alignment

X

Zoom to Extent
For more information, see Zooming

X

Zooming

You have different options to zoom images in ZEN Connect. You can zoom images in and out of a field of view (FOV). As a prerequisite, a ZEN Connect project is loaded.

Zooming to

  1. In the Project tree view, select an image, right-click > Zoom to. Alternatively, click Context menu

    and select Zoom to. The function is also available from the context menu of the image in the Image view.
  1. The image is centered in the view space of the Image view.

Zooming to 100%

  1. In the Project tree view, select an image, right-click > Zoom to 100%. Alternatively, click Context menu

    and select Zoom to 100%. The function is also available from the context menu of the image in the Image view.
  1. The image is zoomed in the view space of the Image view to 100%.

Zooming to extent

  1. In the button bar above the Image view, click Zoom to Extent
    .
    Alternatively, click Context menu

    and click Zoom to Extent.
  1. In the Image view, the sample holder is centered. All images in the ZEN Connect project are displayed.

Moving or Hiding Images

In the Layers view, you can move images over and under other images, or hide them completely.

  1. You have loaded a Connect project with at least two images.
  1. To change the image order, in the Layers view, move the image by dragging it up or down.
  2. In the Image view, the changed order is immediately visible.
  3. To hide the image from the Connect project, in the Layers view, activate or deactivate the image by clicking the Eye icon on the right of the image name. Alternatively, in the Project view, right-click Show/Hide.
  1. The results of your changes are displayed immediately in the Image view.

Removing Data

You can remove images from your ZEN Connect project. The data files will not be deleted from your disk.

  1. In the Project tree view, select an image, right-click Remove Data. Alternatively, click Context menu

    and select Remove Data. The function is also available from the context menu of the image in the Image view.
  1. The selected image is removed from the ZEN Connect project.

Renaming Data

  1. You have loaded a ZEN Connect project.
  1. In the Project view, in the Layer view, or in the Image view, select an image to rename, and choose Rename Data. Alternatively, click the Context Menu

    and choose Rename Data or press the F2.
  2. The corresponding image name is activated in the Project or Layer view.
  3. Rename the image.
  1. You have renamed the image. It is updated either in the Layer view or in the Project view respectively, as well as in the Image view.

Starting a New Session

To organize your work or if you have moved your sample, you can start a new session within your ZEN Connect project any time.

  1. You have loaded a ZEN Connectproject.
  1. In ZEN Connect in the Project or Layers view, click the Context menu
    ,
    and click New Session.
  1. A new session is activated. As soon as you acquire a new image, a new session node is created, and the new image will be subordinated. Note that you have to perform again an alignment of the newly created session to the old data.

Clear Alignment

  1. You have activated the alignment process and have aligned images.
  1. Click Context menu > Clear Alignment.
  2. The session is restored to its un-aligned state.