|
Parameter |
Description |
|
|---|---|---|
|
|
||
|
- |
New |
Creates a new Guided Acquisition setting. Enter a name for the setting. |
|
- |
Rename |
Renames the setting. |
|
- |
Save |
Saves a modified setting under the current name. An asterisk indicates the modified state. |
|
- |
Save As |
Saves the current setting under a new name. Enter a name for the setting. |
|
- |
Import |
Imports an existing setting. |
|
- |
Export |
Exports the current setting. |
|
- |
Delete |
Deletes the current setting. |
|
Repeat Full Guided Acquisition Workflow |
Activated: Displays parameters to repeat the entire workflow over time. |
|
|
Cycles |
Only visible if Repeat Full Guided Acquisition Workflow is activated. |
|
|
Interval |
Only visible if Repeat Full Guided Acquisition Workflow is activated. |
|
|
Object Detection Dropdown |
Only visible if Repeat Full Guided Acquisition Workflow is activated. |
|
|
- |
Keep Iterating if no Object Detected |
Continues to iterate even if no objects are detected. |
|
- |
Stop Guided Acquisition if no Object Detected |
Stops Guided Acquisition if no objects are detected. |
|
- |
Keep Acquiring Scenes without Analysis Findings |
Only visible if your overview experiment contains a setup with multiple scenes. |
|
- |
Exclude Scenes without Findings in Following Iterations |
Only visible if your overview experiment contains a setup with multiple scenes. |
|
- |
Exclude Wells without Findings in Following Iterations |
Only visible if your overview experiment contains a setup with multiple wells. |
|
Overview Scan |
Defines the settings for the overview scan. |
|
|
- |
Experiment |
Selects the experiment setup to acquire the overview scan. |
|
- |
Order |
Only visible if your overview experiment contains a setup with multiple scenes or wells.
|
|
- |
Objective |
Selects the appropriate objective for the overview scan (typically with a low magnification). If the objective has already been defined in the experiment, it is read only (greyed out) here. |
|
- |
Optovar |
Only visible if an optovar is available. Selects the optovar for after magnification of the overview scan. If the optovar has already been defined in the experiment, it is read only/greyed out here. |
|
- |
Find Surface before Overview Experiment |
Only visible if Definite Focus is licensed. Performs a Find Surface before the overview scan. This step is independent from and additional to any focusing strategy defined in the overview experiment. |
|
- |
SW Autofocus before Overview Experiment |
Performs a SW Autofocus before the overview scan and sets the found z-position as z-position for the overview scan. This step is independent from and additional to any focusing strategy defined in the overview experiment. |
|
- |
Initial Range |
Only available if SW Autofocus is activated. Sets the range for the software autofocus. |
|
Processing |
Displays a section for processing steps to process the overview image before it is analyzed. |
|
|
- |
Add Processing Method |
Adds a step for a new processing method. |
|
- |
Method |
Selects a processing method from a drop-down list.
|
|
- |
Setting |
Selects the setting for the processing method from the drop-down list. |
|
- |
|
Removes this entire processing step. |
|
Image Analysis |
Defines the image analysis parameters for the workflow. |
|
|
- |
Setting |
Selects the image analysis setting used to analyze the overview scan. |
|
- |
Class |
Only visible if you have selected an analysis setting where more than one class is defined. |
|
- |
Add Stop Criterion for Detailed Scans |
Activated: Displays options to define a stop criterion for the detailed experiment. |
|
- |
Select Feature |
Only visible if Add Stop Criterion for Detailed Scans is activated. |
|
- |
Select Order |
Only visible if Add Stop Criterion for Detailed Scans is activated. |
|
- |
Random Selection |
Only visible if Add Stop Criterion for Detailed Scans is activated. |
|
- |
Max. Objects |
Only visible if Add Stop Criterion for Detailed Scans is activated. |
|
Repeat Detailed Scan |
Activated: Displays parameters to repeat the detailed scan over time. |
|
|
Cycles |
Only visible if Repeat Detailed Scan is activated. |
|
|
Interval |
Only visible if Repeat Detailed Scan is activated. |
|
|
Detailed Experiment |
Defines the settings for the detailed scan. |
|
|
- |
Experiment |
Selects the experiment setup to acquire a detailed scan at the position of each object detected by the image analysis. |
|
- |
Objective |
Selects the appropriate objective for the detailed scan (typically with high magnification). If the objective has already been defined in the experiment, it is read only/greyed out here. |
|
- |
Optovar |
Only visible if an optovar is available. Selects the optovar for after magnification of the detailed scan. If the optovar has already been defined in the experiment, it is read only/greyed out here. |
|
- |
Find Surface before First Detailed Experiment |
Only visible if Definite Focus is licensed. Performs a Find Surface before the first detailed scan. This step is independent from and additional to any focusing strategy defined in the detailed experiment. |
|
- |
SW Autofocus before First Detailed Experiment |
Performs a SW Autofocus before the first detailed scan and sets the found z-position as z-position for the detailed scan. This step is independent from and additional to any focusing strategy defined in the detailed experiment. |
|
- |
Initial Range |
Only available if SW Autofocus is activated. Sets the range for the software autofocus. |
|
- |
Recall Focus before each Detailed Experiment |
Only visible if Definite Focus is licensed and if Find Surface before First Detailed Experiment is activated. Restores the saved focus position and applies it for each detailed experiment. |
|
Output Folder |
||
|
- |
Output Folder |
Determines the folder where the analysis results are saved. |
|
Open Output Folder after Execution |
Activated: Opens the output folder after Guided Acquisition is finished. |
|
|
Start |
Starts Guided Acquisition. |
|