Training User Interface Intellesis Object Classification

1

Classification Settings
Here you can set the classes for labeling/ classifying the objects. For more information, see Classification Settings.

2

Image View
Here you have your analyzed image and can label the objects by clicking on them.

3

Table
This table displays your analysis results and can be used for labeling the objects in your image. For additional information, see Object Classification Table.

4

Image Gallery
Here you can import and select the images you want to use for classification. For more information, see Image Gallery (Object Classification).

5

View Options
Here you have some general view options of the Dimensions Tab and Display Tab as well as specific labeling options on the Labeling Options Tab.

Classification Settings

Parameter

Description

Model

Displays the model name.

Selected Region Class

Displays the region class selected for classification.

Selected Channels

Displays the channels selected for classification.

Classes list

Displays all the classes for classifying the objects. The color of the class can be changed by clicking on the color field. Renaming of a class is possible by right click menu.

Add Class

Adds a new class to the Classes list.

Delete Class

Deletes the currently selected class from the list.

Train & Classify

Starts the training for the object classification setting.

Display

Label

Displays the labels in the image.

Prediction

Only available after a training has been performed.
Displays the predictions in the image.

Finish

Saves the classification setting and closes the setup.

Cancel

Closes the setup without saving the changes.

Labeling Options Tab

Parameter

Description

Mode


Selection

Activates the selection mode. You can select objects in the image without labeling them.


Labeling

Activates the labeling mode. You can label the objects in your image.


Erase

Activates the erasing mode. You can erase the labels in your image.

Object Display

Sets how the label are displayed in the image.

Fill

Displays the label as filled objects.

Outline

Displays the label as an outline.

Opacity

Sets the opacity of the label in the image.

Object Classification Table

Here the analyzed objects of the image are displayed. You can also use the table to label the objects, see Creating and Training an Intellesis Object Classification Model. This table is linked to the image, which means selecting a row in the table centers the view on the respective object in the image and vice versa. If the image is not zoomed to extent, a click on an object in the table centers this object in the image view and adapts the zoom level if necessary (by zooming out). The table can be sorted by each column by simply clicking on the header.

The table only displays the measurements features selected inside the image analysis, not the ones that are used internally to classify the objects.

Parameter

Description

ID

Displays the unique ID of the objects in the analyzed image.

Label

Displays the label class attributed to the respective object.

Prediction

Displays the predicted label using all labels from all available images.

Confidence

The confidence value in % for the predicted label of every individual object.

Measurement features

Additionally to ID and Label, the values of the various Measurement Features are displayed in the table.