New & Noteworthy
- New Multi Run for the Analysis Panel: run the pipeline for multiple wells or fields of a well plate document
- Retain selected tags when switching between wells or image sets
- Accurately detecting cells and nuclei of varying sizes with the new Cellpose-SAM model
- More intuitive rotation in 4D Viewer using the trackball rotation mode
High Content Analysis
- new: run an analysis pipeline for selected well or fields with the new Multi Run mode
- new: interactively select wells and fields for the analysis multi run with a new well picker
- new: show hierarchical state and progress while running a pipeline over multiple fields and wells
- new: explore the results of already finished wells while the pipeline for other wells is still running
- new: stick to the currently selected tag selection while switching between different wells or fields
- new: stick to the current channel visibility while switching between different wells or fields
- new: distinguish different image types for a single well or field (e.g. fluorescence z-stack, bright-field or maximum intensity projection)
Analysis
- new: Convert Traces to Segments operation
- new: Cellpose-SAM (CPSAM) model is available in the Cellpose-based Segmenter operation
- improved: Segment Morphology operation has additional parameters for some methods
- improved: show a warning in the Batch Analysis if output files with the same name would be generated (and would overwrite each other)
- improved: DL reconstruction speed up by better utilization of GPU resources
- improved: better progress while downloading models from arivis Cloud AI Model Store
- improved: error handling for the Export Surfaces operation
- fixed: some minor bugs for the ML Trainer (Objects) and ML Trainer (Image)
- fixed: issues with the objects in the DL Trainer if classes or training has been renamed before drawing
- fixed: potential problem with continue training if multiple image sets are used in the DL Trainer
- fixed: some rounding issues in the max distance field of the Compartments operation
- fixed: potential crash with Magic Wand on CZI data
- fixed: a problem with large planes in CZI data if used with arivis Cloud models in DL Segmenter
- fixed: do not reset the object selection when switching viewer types (while showing objects from the Analysis pipeline)
General
- new: do not reset object filter (e.g. selected tag) when switching between image sets
- new: do not reset channel visibility when switching between image sets (with the same number of channels)
- new: the Preview Features dialog allows you to activate and test early results for newly added features
- new: the arivis Pro help content is provided by the ZEISS help viewer now
- improved: help content layout
Objects
- new: ability to represent feature values as colorful bars normalized to min / max of the Summary (if enabled)
- improved: detection in the AI-assisted mode in the Draw Tool for data zoomed > 100%
- improved: selection of (overlapping) objects in 2D
- improved: help content for object store types and the context menu of the Objects dialog
4D Viewer
- new: Quick Movie Export - export like you see it in the viewer
- new: intuitive rotation of 3D data using the trackball rotation mode
- new: dedicated Rotate tool
- new: improved positioning of clipping planes with handles
- improved: cursor feedback for axis-specific rotation with right mouse and XYZ key
- improved: more anti-aliased selection line
- fixed: prevent artifacts on volume boundaries with inverted opacity curve
- fixed: prevent object render problems with some specific NVIDIA driver versions
- fixed: avoid problems with missing permissions for the clipboard on copy / paste of opacity settings
Data Handling & Import
- new: import image type for well plate data (e.g. fluorescence z-stack, bright-field or maximum intensity projection)
- new: include image type (if available) in the default name for the imported image set
- improved: import tiled LaVision FastTile Blaze data
- improved: normalization of the color range for CZI float datasets
- improved: support added for more compression types of HDF5 blocks (e.g. used by some IMS datasets)
- fixed: potential wrong colors were imported from some Aperio-SVS data
- fixed: wrong pixel size imported from some Aperio-SVS data
- fixed: import of different image types as channels from Yokogawa
- fixed: import of BigDataViewer with non-consecutive setups
- fixed: some CZI appear blank if opened but not imported
Misc
- new: Docker Desktop is now an optional download in the arivis Pro installer
- new: includes a Docker Desktop license covering running arivis Cloud models in arivis Pro
- removed: Extended Focus has been retired
- several additional bug fixes and stability improvements